Air compressor installation Requirement
1.
Install
the compressor unit on a solid, level floor suitable for taking its weight
2.
Position
of the compressed air outlet valve.
Air
compressor pressure drop calculation is given bellow
DP = (L X 450 X Qc=1.85
)/ (d5 X P )
Where,
D=
Inner diameter of the pipe in mm
DP = Pressure drop in bar, pressure
drop maximum considered 0.1 bar
L=
length of pipe in m
P=
Absolute pressure at the compressor outlet in bar
Qc
= Free air delivery of the compressor in l/s
It
must be follow the connection of the of the compressor air outlet pipe is made
on top of the main air net pipe in order to minimize carry-over of possible
condensate residue.