Skip to main content

Posts

Showing posts with the label Air compressor solenoid valve problem

How one solves the Problem of Air Compressor?

Problem solving of Air compressor Caution Warning Before start working on Air Compressor must be follow this caution Before carrying out any maintenance, repair work or adjustment, press the stop button, wait until the compressor has stopped, press the emergency stop button and switch off the voltage. Close the air outlet valve and lock it if necessary. Problem of Air Compressor Condition 1: Compressor starts running but does not load after delay time. Fault: 1.       Solenoid valve out of order 2.       Inlet valve stuck in closed position 3.       Leak in control air flexible 4.       Minimum pressure valve leaking when net is depressurized Remedy 1.       Replace solenoid valve 2.       Check the valve 3.       Replace leaking flexible 4.       Check the valve Problem of Air Compressor Condition 2: Compressor does not unload, safety valve blows Fault: 1.       Solenoid valve out of order 2.