Initial
Checking procedure of Generator Alternator
Visual
Inspection procedure of Generator Alternator
Firstly one check the drive belt and alternator
pulley to be sure the alternator is rotating.
One must follow this caution for one’s own safety.
Batteries
can emit explosive gases. To reduce the possibility of personal injury, always
ventilate the compartment before servicing the batteries. To reduce the
possibility of arcing firstly one should remove negative battery cables and
then attach the battery cables last.
Check
the battery and all wiring connections.
Inspect
the wiring for defects. Check all connections for tightness and cleanliness,
including the slip connectors at the alternator and engine compartment bulkhead
and connections at the battery.